Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13678439

- Product Categories
- Friendly Links
Information Name: | RBLD-1 sulfur hexafluoride leak detector quantitative Price |
Published: | 2015-06-03 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Introduction RBLD-1 SF6 gas leak detector quantitative principle is: when the air contains changes in the concentration of sulfur hexafluoride gas, the mixed gas under the effect of high frequency electromagnetic field of their degree of ionization will be different, by detecting the degree of ionization to reflect the concentration of sulfur hexafluoride. Another name portable SF6 gas leak detector quantitative, quantitative leak sulfur hexafluoride Features RBLD-1 SF6 gas leak detector using a small vacuum pump quantitative, probe and the host for the split. Small size, light weight, portable, high sensitivity, good stability, fast response, the probe is not toxic, does not produce toxic gases and so on. And a liquid crystal display of gas concentration, more convenient and accurate instrument readings. RBLD-1 SF6 gas leak detector quantitative new alarm setting function, when the measured gas concentration is greater than or equal to the set value, that is its own alarm. RBLD-1 SF6 gas leak detector quantitative dedicated to electric power, railways, electronics manufacturing, chemicals, fire fighting equipment and atomic physics research and other departments are filled with sulfur hexafluoride equipment, containers leak, you can quickly and accurately qualitative and quantitative detection. MOA tester operation OF: Pilot High measurement time: 2012-7-2 Read: Pilot testing of high zinc oxide arrester tester operation: Wireless mode uses wireless transmission terminal to PT secondary voltage signal is transmitted to the instrument The voltage acquisition part. So instead of PT's long-term connection. Wireless transmission terminal connected to neutral black clip (x), red clamp connection B phase. Near two small clip at each of a 0.1A fuse, to prevent accidental PT blown fuse. Should be replaced with the same size fuse 0.1A fuse after damage. Current signal leakage current first signal line plug into the instrument, after the clamps to the other end (or by insulating pole ride to) the upper end of the test phase MOA discharge counter. The test chamber can be no discharge counter MOA put insulation board, take the lower end of the current signal from the MOA. There was a close clip at 0.1A fuse for preventing misconnection PT. Should be replaced with the same size fuse after the fuse is damaged. Current signal not use extension cords. Wired mode instrument input PT secondary voltage as the reference signal, while input MOA current signal can be obtained through the Fourier transform of the fundamental voltage U1, current fundamental peak voltage and current Ix1p angle Φ. Therefore phase with the voltage resistive current fundamental component peak (Ir1p), quadrature component is the capacitive current fundamental peak (Ic1p): Ir1p = Ix1pCOSΦIc1p = Ix1pSINΦ taking into account δ = 90 ° -Φ equivalent dielectric loss angle, directly MOA with Φ evaluation is very simple: there is no time "phase interference", Φ mostly between 81 ° ~ 86 °. Press "resistive current can not exceed 25% of the total current" requirement, Φ not be less than 75.5 °, refer to the following table for MOA segment performance rating: Performance 89 ° sensing mode setting on the electric field induced sensor MOA base, which induced current advance electric field intensity (bus voltage) 90 °, after the integral calculation of field strength or bus voltage in phase, thus inducing an electric field sensor signal as a measurement reference. Electric field sensing instrument input sensor signal, while the input current signal MOA, the electric field can be obtained through the Fourier transform fundamental E1, Ix1p current fundamental peak electric field and current angle Φ. Phase component of the electric field resistive current fundamental peak (Ir1p), quadrature component is the capacitive current fundamental peak (Ic1p). Use B-phase induction signal as a reference because the A / C two opposite sides of the base electric field B phase offset, the tablet should be provided to the B phase MOA base and A / C phase symmetrical position, you can get the B phase right phase information. A / C with MOA base electric field effect by the B phase, not the sensor plate provided to the A / C phase MOA base. Three identical measure grounding: connect the ground wire before measuring, measuring after the last demolition ground! If the ground of paint or rust must be removed. Reference voltage on the reference voltage signal cord into the socket, the other end of the B-phase PT secondary voltage output. Near two small clip at each of a 0.1A fuse, to prevent accidental PT blown fuse. Should be replaced with the same size fuse 0.1A fuse after damage. Current signal leakage current first signal line plug into the instrument, after four clips clip the other end to (or through an insulating pole ride to) A, B, C phase MOA Discharge counter top and ground. There was a close clip at 0.1A fuse for preventing misconnection PT. Should be replaced with the same size fuse after the fuse is damaged. Current signal not use extension cords. Inferior difference in gifted interference should actually attract attention Φ <80 ° when. Ground: to connect the ground wire before measuring, measuring after the last demolition ground! If the ground of paint or rust must be removed. Reference voltage on the reference voltage signal cord into the socket, the other end of the test phase PT secondary voltage output: black clip connection neutral point (x), red clip-phase voltage measurement reception (a / b / c). Then the outer casting measure boosting transformer measuring winding. If the PT distance, you can use an extension cord. Near two small clip at each of a 0.1A fuse, to prevent accidental PT blown fuse. Should be replaced with the same size fuse 0.1A fuse after damage. Current signal leakage current first signal line plug into the instrument, after the clamps to the other end (or by insulating pole ride to) the upper end of the test phase MOA discharge counter. The test chamber can be no discharge counter MOA put insulation board, take the lower end of the current signal from the MOA. There was a close clip at 0.1A fuse for preventing misconnection PT. Should be replaced with the same size fuse after the fuse is damaged. Current signal not use extension cords. Accessories This product is a detailed list, please refer to the instructions or the Agency Agreement shall prevail Name Description Quantity instrument host / vacuum pump oil 1/2 bottle Manual / a Inspection Report / 1 Certificate / a Notes: 1. the actual appearance of the product Products subject to technical parameters and models are subject to change without notice, if any misappropriation or copying behavior, will be held liable. 2. For more product information, please Pilot Power products center, service hotline: 400-046-1993. |
Admin>>>
You are the 16732 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan high test pilot Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16732 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan high test pilot Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility