Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13678439

- Product Categories
- Friendly Links
Information Name: | ZSBL-IIIMOA-30 MOA detector Price |
Published: | 2015-06-03 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Accessories This product is a detailed list, please refer to the instructions or the Agency Agreement shall prevail Name Description Quantity instrument host / 1 set test leads / 2 wearing parts (CA3140E) 1-chip power cord AC220V 1 根 Manual / a Inspection Report / 1 Certificate / a Notes: 1. Product appearance to real product, technical parameters and models are subject to change without notice, if any misappropriation or copying behavior, will be held liable. 2. For more product information, please Pilot Power products center, service hotline: 400-046-1993. DC resistance tester should pay attention to what issues OF: Pilot High measurement time: 2012-6-26 Read: Pilot high DC resistance tester testing security measures: 1, must be carefully read this manual before using the instrument. 2, operation of the instrument should have general electrical knowledge. 3, the instrument uses to avoid rain, corrosive gas, dust too thick, heat, direct sunlight and other places. 4, the instrument should avoid excessive vibration. 5, after the test must wait for discharge alarm sound stops and then turn off the power and remove the test leads. 6, measuring no-load tap changer, must wait for the discharge instruction to stop the alarm sound, switch gear. 7, in the testing process, you prevent the test clip and power lines. DC Resistance Tester Note: 1, for non-load tap winding, are not allowed during the test or when the electricity is switched without load tap discharge. 2, the sense of resistance to the test object, without completely discharged (when the buzzer sounds) case, does not allow removal of the test line, from electric shock. 3, encountered during testing external AC220V sudden power failure, the instrument will start automatically discharge at this time does not allow removal of the test line immediately before stitches after 5 minutes. Product parameters 1, measuring range: Voltage: 0 ~ 30kV ripple factor: ≤1.5% Current: 0 ~ 1000μA 2, Resolution: Current: 0.5μA voltage: 0.1 kV 3, built-in power charging time: 2-3 hours 4, Built-in power usage time: ≥4 hours 5, Remote control effective distance: 100M 6, ambient temperature: -10 ℃ ~ 50 ℃ 7, relative humidity: 25 ℃ when ≤85% 8, Altitude: <1000M 9, charging voltage: AC100V -240V 10, power frequency: 50 ± 1HZ Notes: 1. Appearance actual product, technical parameters and models are subject to change without notice, if any misappropriation or copying behavior, will be held liable. 2. For more product information, please Pilot Power products center, service hotline: 400-046-1993. Introduction ZSBL-III MOA tester is specifically designed to detect 10kV and below the power system with no gap between MOA MOA valve electrical contact failure of internal defects, according to "preventive test code for electrical equipment" DL / T596-1996 provisions of 14.2, power plants, substations and, if necessary, an annual pre-season thunderstorm MOA should do 1mA DC voltage (U1mA) and leakage current detection 0.75 U1mA under. The company according to the needs of field measurements the instrument has been improved, the DC high voltage power supply, measurement and control system combine to reduce equipment size and weight. Operation Set humane, achieve remote control as measured by remote control, and based on the measurement procedures required to automatically measure the ambient temperature increased functionality, with a large capacity memory, can store 50 groups of test data, non-volatile. With high-speed thermal printer greatly improves print speed test results. Power system and MOA plant site inspection essential equipment. Another name MOA-30kV microcomputer MOA DC tester, MOA-30 Smart MOA tester, MOA-30 MOA tester, MOA-30 MOA tester, MOA DC leak tester features 1, the temperature measurement: automatically senses the ambient temperature and recorded in the test results. 2, the remote test: Remote Remote Test by remote control, to make the test more secure, convenient and fast. 3, the internal power supply: AC220V AC power can be used, but also by using the built-in rechargeable battery. 4, easy to use: Chinese menu operation, the measurement data display and intuitive, built-for-paper printer before changing paper convenience, print speed. 5, measurement accuracy: Full digital processing, built-in sophisticated mathematical model, high accuracy, good reproducibility of test results. 6, can store 50 groups of test data, non-volatile, and can always see print. 7, easy to carry: height, size, weight of competing products, 30% - 70% easy to carry. 8, fully functional: measurement, display, clock, temperature, result print in one step. |
Admin>>>
You are the 16732 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan high test pilot Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 16732 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan high test pilot Electric Co. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility